Nellcor N-6000 UltraCap C02 Monitor with Sp02 - 6 Months warranty -

Nellcor N-6000 UltraCap C02 Monitor with Sp02 - 6 Months warranty -

$675.00

Nellcor N-6000 UltraCap CO2 Monitor with SpO2

It comes with 6 month warranty by SBI Medical LLC, an unique warranty certificate comes inside the box.

Includes:

Brand new SpO2 finger sensor

Power cord

Brand new battery

Biomed certified preventive maintenance label

Features:

CO2/SpO2 with waveform 

 Microprocessor-controlled instrument for continuous real-time monitoring for oxygen saturation (SpO2), pulse rate (PR), end tidal carbon dioxide (ETCO2), and respiratory rate (RR). 

Quantity
Last items in stock

 

Secure Payment

 

Insured and Tracked Shipping

Specifications:

Size 104mm H x 302mm W x 257mm D (4.1” x 11.9” x 10.1”) 

Weight 13 lbs (6kg) 

Display Type: vacuum fluorescent & LEDs. Display are: 140.6mm x 35mm. Resolution: 256 x 64 pixels. Pixel size: 0.4 x 0.4 mm 

Controls and Indicators Front panel: on/standby; freeze; menu; pulse tone volume, up and down; alarm off; alarm off indicator; battery charging indicator; function keys (4), software configured. Rear panel: mains AC power ON/OFF control. 

Connections Front panel: connector for mainstream CO2 sensor cable; connector for SpO2 cable. Rear panel: power cord receptacle; fuse block; RS-232 input/output port; C-lock ECG synchronization input (3/32” mono phone jack). 

Capnograph Display range: 0-99 mmHg. Breath rate: 0-150 breaths/min. Accuracy: ±2 mmHg for 0-40 mmHg, ±5% of reading (increasing linearity 0.8% for every 10 mmHg) for 41-99 mmHg. Response time: less then 60 ms. Alarms: apnea; sensor disconnect; high/low ETCO2; high/low breath rate; high/low inspired CO2. 

Pulse Oximeter Display ranges: 0-100% SpO2, 20-250 beats/min pulse rate. Accuracy: Adults: 70%-100% ±2 digits, 0-69% unspecified; Neonates: 70%-95% ±2%, 0-69% unspecified. Wavelengths: 660 nm (red, nominal); 920 mm (infrared, nominal). Heat dissipation: non-heated: less than 50 mW total heat dissipation by LEDs (typically less than 1° C temperature rise). Alarms: pulse search; high/low SpO2; high/low pulse rate; SpO2 sensor disconnect. 

CO2 Sensor Type: mainstream. Size: <12.5 mm³ (0.5 in³). Weight: less than 10 grams. Cable length: 3 meters (9.84 feet). Calibration: annual accuracy check; no user calibration required. Temperature: 42°C nominal 

Electrical Power requirements: 100/120V ~, 50/60 Hz, 500 mA; 220/240V ~, 50/60 Hz, 250 mA. Digital/Analog input voltage: ±30 VDC, maximum. Leakage current: 10 µA maximum (for 110V; 20 µA maximum for 220V) from patient connections to ground or AC mains; 100 µA maximum from AC mains to chassis ground. 

Battery Type: sealed lead acid. Operating time (fully charged): 90 minutes nominal, 180 minutes without graphics. Recharge period: 12 hours typical. Charger type: internal, current limited, constant voltage. Battery fuse: 1 X T 2.5 A, 250V, 3 AG. 

AC Fuses 100/120 V ~ 1 XT 1.0 A, 250V, 3AG; 220/240 V~ 2 X T 0.5 A, 5x20 mm